Nextep FRP Ladders - Installation

Field assembly must include the following procedures.

  • Ladders are laid out on a flat surface, bracket side down to avoid scratching the stiles.
  • Sections are placed in sequence according to the supplied plan.
  • All bracket fasteners to be loosened off, as brackets are tightened prior to transport and will need considerable movement for assembly to be achieved. A rubber mallet (not steel) should be used on the ends of stiles and not the rungs to aid in the assembly process.
  • All fixing bolts to be suitably tightened once assembly of individual sections is completed.
  • Assembled ladders should be turned sideways for carrying and lifting, to avoid bending at the joining bracket areas.

  • Gallery

      Image 1  |   Image 2  |   Image 3  |  Image 4  |  Image 5

    The installation area must be assessed for best positioning of the ladder onto flat wall surfaces. The ladder has a four bolt-fixing configuration on the top bracket. Coloured reflectors on the rungs follow International Safety Codes for Red/LHS and Green/RHS.

    Fasteners should be 316 Stainless steel Chemical bolts (12mm X 80mm) or 316 Stainless steel Sleeve anchor type bolts sealed with a chemical resistant epoxy. This will ensure similar life expectancies from both ladder and fixing anchors.